Characteristic | LEVDC Charger – Single Gun | LEVDC Charger – Dual Gun | |||
Power | Rated Power | 3 kW | 6 kW | 6 kW | 12 kW |
Input voltage | 200-265Vac, 1 phase (L- N-PE), 50±1Hz | 346-412Vac, 3 Phase (L1,L2,L3,N,PE), 50±1Hz | 346 - 412Vac, 3 phase (L1,L2,L3,N,PE), 50±1Hz | ||
Number of Output | 1 | 2 | |||
Output Charging Outlet | 1 x 3kW (IEC62196-6 Type 6) | 1 x 6kW (IEC62196-6 Type 6) | 1 x 6kW (IEC62196-6 Type 6) | 2 x 6kW (IEC62196-6 Type 6) | |
DC Output Voltage | 40-68Vdc | ||||
DC Output Current | 50A per output | 100A per output | 50A per output | 100A per output | |
Battery Backup | Battery Backup for controlling unit > 60 mins | ||||
Efficiency | ≥92% | ||||
Power Factor | >0.95 |
Controls and User Interface |
Display | 4.3°HMI LCD Display Touchscreen (Faults / Charging status/ Supply/ Connectivity status) | ||||
LEDs | LEDs for charging/fault modes | |||||
User Authentication | RFID + OCPPv1.6 |
Environment | Ambient emperature | 0°C to 55°C | ||||
Storage Temperature | -20°C to 85°C | |||||
Altitude | <2000 Mtr | |||||
Humidity | <95%, Non condensing |
Communication | External | WiFi, LAN / 4G (with signal boosting Antenna), RS485, OCPPv1.6 | |||
Metering and Billing | Class 1 Energy Metering | ||||
Charging Operation | RFID Card / QR Code / Mobile CMS App (OCPPv1.6) |
Protection/Safety | Input/ Output protection | Over/Under Voltage, Overload, Short Circuit, Current Leakage, Grounding, Surge protection, Relay Welding, Over Temperature | ||||
Mechanical Protection | Enclosure Mechanical Strength IK-08, IP55 for Outdoor use, Flame Retardant Grade UL94 V-0, Anti-Theft Mounting Design, Safety Lock | |||||
Mounting | Wall/ Stand Mount | Wall / Pole Mount / Floor Mount (Anti-Theft Design) | ||||
Push Button | Mushroom Push Button for Emergency Stop | |||||
Cooling | Forced Air Cooling |
Certification | As per | IEC 61851 / AIS 138 Part-1 / IS-17017 |